<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-8394680923097880543</id><updated>2011-12-14T19:10:27.125-08:00</updated><category term='GM7S'/><category term='GE'/><category term='Electrical Contacts'/><category term='Cutler Hammer'/><category term='Before and After'/><category term='FPE'/><category term='Swtiches'/><category term='Westinghouse'/><category term='Finger Clusters'/><title type='text'>WW Components, Inc.</title><subtitle type='html'>Specializing in the repair and manufacture of electrical contacts and related switchgear</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://wwcomponents.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>76</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-1069043199170116103</id><published>2011-12-14T19:09:00.000-08:00</published><updated>2011-12-14T19:10:27.133-08:00</updated><title type='text'>Contact Fingers</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/-kXzURh2vlL4/TullGYKDh7I/AAAAAAAAAPg/_q4UA9GTBAs/s1600/fingers.TIF"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 400px; height: 146px;" src="http://4.bp.blogspot.com/-kXzURh2vlL4/TullGYKDh7I/AAAAAAAAAPg/_q4UA9GTBAs/s400/fingers.TIF" border="0" alt=""id="BLOGGER_PHOTO_ID_5686187164770207666" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-1069043199170116103?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1069043199170116103'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1069043199170116103'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/12/contact-fingers.html' title='Contact Fingers'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/-kXzURh2vlL4/TullGYKDh7I/AAAAAAAAAPg/_q4UA9GTBAs/s72-c/fingers.TIF' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8843711533391646414</id><published>2011-09-30T12:43:00.000-07:00</published><updated>2011-09-30T12:44:25.360-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>No Load Tap Changer Parts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/-xwOuwHPWiDU/ToYcBKT2auI/AAAAAAAAAPY/uiNJo7fcxRc/s1600/noloadtapchanger.BMP"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 254px;" src="http://3.bp.blogspot.com/-xwOuwHPWiDU/ToYcBKT2auI/AAAAAAAAAPY/uiNJo7fcxRc/s400/noloadtapchanger.BMP" border="0" alt=""id="BLOGGER_PHOTO_ID_5658240788110666466" /&gt;&lt;/a&gt;A set of no load tap changer parts made from original OEM samples.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8843711533391646414?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8843711533391646414'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8843711533391646414'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/09/no-load-tap-changer-parts.html' title='No Load Tap Changer Parts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/-xwOuwHPWiDU/ToYcBKT2auI/AAAAAAAAAPY/uiNJo7fcxRc/s72-c/noloadtapchanger.BMP' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-1868831357169227150</id><published>2011-09-20T12:29:00.000-07:00</published><updated>2011-09-20T12:30:36.723-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse DHP Movable Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/-LV_4iATpWb8/TnjpoHNZz3I/AAAAAAAAAPQ/AHJrmnEa2FE/s1600/dhp.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 206px;" src="http://4.bp.blogspot.com/-LV_4iATpWb8/TnjpoHNZz3I/AAAAAAAAAPQ/AHJrmnEa2FE/s400/dhp.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5654526207502962546" /&gt;&lt;/a&gt;&lt;br /&gt;Westinghouse DHP movable contact assembly with right and left hand side blades and center arcing contact.  When we repaired these contacts, we replaced the damaged red shields.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-1868831357169227150?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1868831357169227150'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1868831357169227150'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/09/westinghouse-dhp-movable-contacts.html' title='Westinghouse DHP Movable Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/-LV_4iATpWb8/TnjpoHNZz3I/AAAAAAAAAPQ/AHJrmnEa2FE/s72-c/dhp.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-7867675450590429948</id><published>2011-09-14T10:00:00.000-07:00</published><updated>2011-09-14T10:00:02.670-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>ITE KS OCB Finger Cluster</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/-HkGyQIXe9jU/Tm53D_v9umI/AAAAAAAAAPI/ZtQ777rWCxo/s1600/ite_ocb.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 344px; height: 400px;" src="http://1.bp.blogspot.com/-HkGyQIXe9jU/Tm53D_v9umI/AAAAAAAAAPI/ZtQ777rWCxo/s400/ite_ocb.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5651585492932475490" /&gt;&lt;/a&gt;ITE Oil Circuit Breaker Finger cluster.  This is one of six clusters (along with six movable rods) that we recently repaired.  We also made the corresponding baffle stacks using phenolic.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-7867675450590429948?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7867675450590429948'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7867675450590429948'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/09/ite-ks-ocb-finger-cluster.html' title='ITE KS OCB Finger Cluster'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/-HkGyQIXe9jU/Tm53D_v9umI/AAAAAAAAAPI/ZtQ777rWCxo/s72-c/ite_ocb.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-1535109703843277766</id><published>2011-09-12T12:26:00.000-07:00</published><updated>2011-09-12T12:27:54.424-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>McGraw Edison 550BLS</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/-NXyTHAslt5M/Tm5c-omEIxI/AAAAAAAAAPA/5z03pqixwwg/s1600/550bls.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 229px;" src="http://3.bp.blogspot.com/-NXyTHAslt5M/Tm5c-omEIxI/AAAAAAAAAPA/5z03pqixwwg/s400/550bls.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5651556813515268882" /&gt;&lt;/a&gt;Repaired McGraw Edison 550 BLS Contacts.  We can repair or manufacture contacts from the 550B and 550C series.  Call for a quote today!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-1535109703843277766?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1535109703843277766'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1535109703843277766'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/09/mcgraw-edison-550bls.html' title='McGraw Edison 550BLS'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/-NXyTHAslt5M/Tm5c-omEIxI/AAAAAAAAAPA/5z03pqixwwg/s72-c/550bls.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4850340374126227293</id><published>2011-06-21T07:15:00.000-07:00</published><updated>2011-06-21T07:16:55.004-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Siemens Size 7 Motor Starters</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/-IL4MF7OMiT8/TgCnipVqlII/AAAAAAAAAO4/k6lKLxQuZww/s1600/sasize7.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 273px;" src="http://3.bp.blogspot.com/-IL4MF7OMiT8/TgCnipVqlII/AAAAAAAAAO4/k6lKLxQuZww/s400/sasize7.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5620676548612494466" /&gt;&lt;/a&gt;A three-pole set of Siemens Size 7 Contacts (49KZ750).  We can repair these and other motor starter electrical contacts!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4850340374126227293?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4850340374126227293'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4850340374126227293'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/06/siemens-size-7-motor-starters.html' title='Siemens Size 7 Motor Starters'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/-IL4MF7OMiT8/TgCnipVqlII/AAAAAAAAAO4/k6lKLxQuZww/s72-c/sasize7.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-7181779588733768648</id><published>2011-03-25T08:26:00.000-07:00</published><updated>2011-03-25T08:26:01.439-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse DR and DH Arcing Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/-lN-qupuMZDA/TYdulcaWyWI/AAAAAAAAAOs/DibXFpLH6hc/s1600/whdhdr.BMP"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 200px;" src="http://1.bp.blogspot.com/-lN-qupuMZDA/TYdulcaWyWI/AAAAAAAAAOs/DibXFpLH6hc/s400/whdhdr.BMP" border="0" alt=""id="BLOGGER_PHOTO_ID_5586555452337342818" /&gt;&lt;/a&gt;Westinghouse DH(left) and DR(right) arcing contacts we just repaired!  We can repair all the contacts from the various types of DH and DR breakers.  Use the contact information on the sidebar or visit our main site: &lt;a href="http://www.wwcomponents.net/"&gt;www.WWComponents.net&lt;/a&gt;.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-7181779588733768648?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7181779588733768648'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7181779588733768648'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/03/westinghouse-dr-and-dh-arcing-contacts.html' title='Westinghouse DR and DH Arcing Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/-lN-qupuMZDA/TYdulcaWyWI/AAAAAAAAAOs/DibXFpLH6hc/s72-c/whdhdr.BMP' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4762510081197510947</id><published>2011-03-23T08:24:00.000-07:00</published><updated>2011-03-23T08:24:01.051-07:00</updated><title type='text'>Westinghouse OCB Contact Stabs</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/-Cr4HPlqZ904/TYdtsykpFkI/AAAAAAAAAOk/etxTtqDuG0c/s1600/whocbstabs.BMP"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 173px;" src="http://2.bp.blogspot.com/-Cr4HPlqZ904/TYdtsykpFkI/AAAAAAAAAOk/etxTtqDuG0c/s400/whocbstabs.BMP" border="0" alt=""id="BLOGGER_PHOTO_ID_5586554479033521730" /&gt;&lt;/a&gt;A set of Westinghouse 34.5 contact stabs we recently manufactured based on the customer's burned up sample.  We used brand new round stock copper and the proper contact tip material to create these pieces.  We can also repair stabs such as these. Call for a quote on the repair or manufacture of electrical contacts today: 205-221-3093.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4762510081197510947?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4762510081197510947'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4762510081197510947'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/03/westinghouse-ocb-contact-stabs.html' title='Westinghouse OCB Contact Stabs'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/-Cr4HPlqZ904/TYdtsykpFkI/AAAAAAAAAOk/etxTtqDuG0c/s72-c/whocbstabs.BMP' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4034225724676145018</id><published>2011-03-21T08:22:00.000-07:00</published><updated>2011-03-21T08:23:57.723-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>General Electric SE-100S Blades</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/-Nf9twCV9UvU/TYdtZ4sDTtI/AAAAAAAAAOc/iagNJKt_g9c/s1600/se100s.BMP"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 223px;" src="http://4.bp.blogspot.com/-Nf9twCV9UvU/TYdtZ4sDTtI/AAAAAAAAAOc/iagNJKt_g9c/s400/se100s.BMP" border="0" alt=""id="BLOGGER_PHOTO_ID_5586554154257698514" /&gt;&lt;/a&gt;General Electric SE-100S Arcing (flicker) Blades.  We can repair and manufacture these to OEM specs.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4034225724676145018?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4034225724676145018'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4034225724676145018'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/03/general-electric-se-100s-blades.html' title='General Electric SE-100S Blades'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/-Nf9twCV9UvU/TYdtZ4sDTtI/AAAAAAAAAOc/iagNJKt_g9c/s72-c/se100s.BMP' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4548805735016667823</id><published>2011-03-17T10:04:00.003-07:00</published><updated>2011-03-17T10:05:23.946-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse DH250 Finger Clusters</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/-OMog8MrgjLQ/TYI_HCCgU7I/AAAAAAAAAOU/FSfSSSM8U0U/s1600/clusters11.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 250px;" src="http://1.bp.blogspot.com/-OMog8MrgjLQ/TYI_HCCgU7I/AAAAAAAAAOU/FSfSSSM8U0U/s400/clusters11.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5585095877931848626" /&gt;&lt;/a&gt;Recently re-silvered finger clusters from Westinghouse DH breakers.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4548805735016667823?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4548805735016667823'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4548805735016667823'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/03/westinghouse-dh250-finger-clusters.html' title='Westinghouse DH250 Finger Clusters'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/-OMog8MrgjLQ/TYI_HCCgU7I/AAAAAAAAAOU/FSfSSSM8U0U/s72-c/clusters11.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8671044959843770680</id><published>2011-02-28T14:03:00.000-08:00</published><updated>2011-02-28T14:05:06.171-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>ITE HV-150 Movable Main Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/-z8a5s_ZbmuA/TWwb6ilpDwI/AAAAAAAAAOM/tmFkhcvszKk/s1600/itejv-150.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 243px;" src="http://2.bp.blogspot.com/-z8a5s_ZbmuA/TWwb6ilpDwI/AAAAAAAAAOM/tmFkhcvszKk/s400/itejv-150.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5578864730936250114" /&gt;&lt;/a&gt;A set of three ITE HV-150 Movable Main contacts re-tipped at our facility using silver tungsten.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8671044959843770680?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8671044959843770680'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8671044959843770680'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/02/ite-hv-150-movable-main-contacts.html' title='ITE HV-150 Movable Main Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/-z8a5s_ZbmuA/TWwb6ilpDwI/AAAAAAAAAOM/tmFkhcvszKk/s72-c/itejv-150.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-7717331503082996812</id><published>2011-02-22T08:52:00.000-08:00</published><updated>2011-02-22T08:53:47.894-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse OCB Stationary Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/-Na8iNDUicfw/TWPp4k0nY-I/AAAAAAAAAOE/bvr3XPOv4K0/s1600/whocbs.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 262px;" src="http://3.bp.blogspot.com/-Na8iNDUicfw/TWPp4k0nY-I/AAAAAAAAAOE/bvr3XPOv4K0/s400/whocbs.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5576557921781113826" /&gt;&lt;/a&gt;A group of Westinghouse OCB stationary contacts.  We just completed making a large batch of these.  We can also manufacture and repair the movable double stabs and arcing horns.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-7717331503082996812?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7717331503082996812'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7717331503082996812'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/02/westinghouse-ocb-stationary-contacts.html' title='Westinghouse OCB Stationary Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/-Na8iNDUicfw/TWPp4k0nY-I/AAAAAAAAAOE/bvr3XPOv4K0/s72-c/whocbs.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-2303796059927927016</id><published>2011-02-11T06:47:00.000-08:00</published><updated>2011-02-11T06:48:34.949-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse B20 Arcing Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/-XazPmC6qC1o/TVVMKR3TCbI/AAAAAAAAAN8/wxrOwNxgYKc/s1600/as.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 183px;" src="http://4.bp.blogspot.com/-XazPmC6qC1o/TVVMKR3TCbI/AAAAAAAAAN8/wxrOwNxgYKc/s400/as.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5572443853418596786" /&gt;&lt;/a&gt;Westinghouse B20 Movable Arcing Contacts made from an original OEM sample.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-2303796059927927016?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2303796059927927016'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2303796059927927016'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/02/westinghouse-b20-arcing-contacts.html' title='Westinghouse B20 Arcing Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/-XazPmC6qC1o/TVVMKR3TCbI/AAAAAAAAAN8/wxrOwNxgYKc/s72-c/as.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-5964508498699876749</id><published>2011-02-10T11:46:00.001-08:00</published><updated>2011-02-10T11:46:57.730-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>General Electric AL Arcing Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/-VqQjQf5YUZI/TVRAkyJpdeI/AAAAAAAAAN0/MaJoYF51CYk/s1600/geal.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 136px;" src="http://3.bp.blogspot.com/-VqQjQf5YUZI/TVRAkyJpdeI/AAAAAAAAAN0/MaJoYF51CYk/s400/geal.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5572149639645853154" /&gt;&lt;/a&gt;General Electric AL Arcing Contacts recently repaired at our shop.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-5964508498699876749?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/5964508498699876749'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/5964508498699876749'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/02/general-electric-al-arcing-contacts.html' title='General Electric AL Arcing Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/-VqQjQf5YUZI/TVRAkyJpdeI/AAAAAAAAAN0/MaJoYF51CYk/s72-c/geal.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-7462477414157298094</id><published>2011-01-27T11:53:00.000-08:00</published><updated>2011-01-27T11:54:59.832-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Sylvania Size 6 Motor Starters</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/TUHNY0kJFNI/AAAAAAAAANk/ff1LE7pWgyk/s1600/sylvansize6.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 295px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/TUHNY0kJFNI/AAAAAAAAANk/ff1LE7pWgyk/s400/sylvansize6.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5566956440717432018" /&gt;&lt;/a&gt;A set of Sylvania Size 6 motor starter contacts we made based on OEM samples, complete with appropriate tip material and silver plated.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-7462477414157298094?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7462477414157298094'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7462477414157298094'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/01/sylvania-size-6-motor-starters.html' title='Sylvania Size 6 Motor Starters'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/TUHNY0kJFNI/AAAAAAAAANk/ff1LE7pWgyk/s72-c/sylvansize6.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8275851024577301339</id><published>2011-01-25T11:54:00.001-08:00</published><updated>2011-01-25T12:00:04.774-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Contact and Bus Work</title><content type='html'>Here is a set of contacts we made and silver plated based on the customer's samples.  In each photo, the original OEM sample is shown along with our brand new parts...&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/TT8qo4FRz9I/AAAAAAAAANc/L1gx1En8QKE/s1600/luis-A.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 274px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/TT8qo4FRz9I/AAAAAAAAANc/L1gx1En8QKE/s400/luis-A.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5566214546190880722" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/TT8qmqGYLTI/AAAAAAAAANU/5r2ZmWpA6g8/s1600/luis-B.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 209px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/TT8qmqGYLTI/AAAAAAAAANU/5r2ZmWpA6g8/s400/luis-B.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5566214508077657394" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/TT8qkGdFrsI/AAAAAAAAANM/7NZ4BrcavHA/s1600/luis-C.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 164px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/TT8qkGdFrsI/AAAAAAAAANM/7NZ4BrcavHA/s400/luis-C.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5566214464149499586" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8275851024577301339?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8275851024577301339'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8275851024577301339'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2011/01/contact-and-bus-work.html' title='Contact and Bus Work'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/TT8qo4FRz9I/AAAAAAAAANc/L1gx1En8QKE/s72-c/luis-A.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-1469934723022480638</id><published>2010-11-22T08:15:00.000-08:00</published><updated>2010-11-22T08:17:33.459-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Telescoping Isolators</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/TOqXIhx28bI/AAAAAAAAANA/3riLu-s26Hw/s1600/telescopingisolators.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 290px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/TOqXIhx28bI/AAAAAAAAANA/3riLu-s26Hw/s400/telescopingisolators.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5542408464195056050" /&gt;&lt;/a&gt;Here's an assortments of parts we made for a Telescoping Isolator; movable contact and upper contact units.  Customer sent in the samples and we were able to make new ones shown.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-1469934723022480638?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1469934723022480638'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1469934723022480638'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/11/telescoping-isolators.html' title='Telescoping Isolators'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/TOqXIhx28bI/AAAAAAAAANA/3riLu-s26Hw/s72-c/telescopingisolators.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8064720920868883293</id><published>2010-11-17T06:30:00.000-08:00</published><updated>2010-11-17T06:32:12.467-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse OCB Movable and Stationary Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/TOPnOQoXIbI/AAAAAAAAAM4/zDgqK29J74s/s1600/stationaries.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 253px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/TOPnOQoXIbI/AAAAAAAAAM4/zDgqK29J74s/s400/stationaries.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5540526198764282290" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/TOPnLCMQ4tI/AAAAAAAAAMw/pRnC1Rx8tjE/s1600/movables.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 262px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/TOPnLCMQ4tI/AAAAAAAAAMw/pRnC1Rx8tjE/s400/movables.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5540526143348728530" /&gt;&lt;/a&gt;Multiple stationary and movable contacts repaired from a Westinghouse OCB breaker.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8064720920868883293?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8064720920868883293'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8064720920868883293'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/11/westinghouse-ocb-movable-and-stationary.html' title='Westinghouse OCB Movable and Stationary Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/TOPnOQoXIbI/AAAAAAAAAM4/zDgqK29J74s/s72-c/stationaries.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-3037528912409817028</id><published>2010-09-23T08:00:00.001-07:00</published><updated>2010-09-23T08:01:45.965-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse DH250 Electrical Contacts</title><content type='html'>Here's a batch of Westinghouse DH-250 arcing contacts we recently repaired....&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/TJtrnnXp_pI/AAAAAAAAAMo/GjBppfn-2NY/s1600/whdh1.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 343px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/TJtrnnXp_pI/AAAAAAAAAMo/GjBppfn-2NY/s400/whdh1.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5520124096599948946" /&gt;&lt;/a&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/TJtrlD4TKpI/AAAAAAAAAMg/kbZvob7KXRc/s1600/whdh2.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 276px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/TJtrlD4TKpI/AAAAAAAAAMg/kbZvob7KXRc/s400/whdh2.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5520124052713450130" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-3037528912409817028?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3037528912409817028'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3037528912409817028'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/09/westinghouse-dh250-electrical-contacts.html' title='Westinghouse DH250 Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/TJtrnnXp_pI/AAAAAAAAAMo/GjBppfn-2NY/s72-c/whdh1.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-498993334414632296</id><published>2010-09-01T13:46:00.000-07:00</published><updated>2010-09-01T13:49:38.795-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse Size 4 Electrical contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/TH671ElvQRI/AAAAAAAAAMY/BJqSutoxjTA/s1600/size4.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 155px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/TH671ElvQRI/AAAAAAAAAMY/BJqSutoxjTA/s400/size4.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5512049514387554578" /&gt;&lt;/a&gt;Besides air circuit and oil circuit breaker contacts, we also repair motor starter contacts.  Here are some we just completed -- Westinghouse size 4 electrical contacts.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-498993334414632296?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/498993334414632296'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/498993334414632296'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/09/westinghouse-size-4-electrical-contacts.html' title='Westinghouse Size 4 Electrical contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/TH671ElvQRI/AAAAAAAAAMY/BJqSutoxjTA/s72-c/size4.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4385260301549108760</id><published>2010-08-30T13:37:00.000-07:00</published><updated>2010-08-30T13:39:00.516-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse 50DH150-E Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/THwWoZxkf_I/AAAAAAAAAMQ/TIc_Ptu23AE/s1600/whdh.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 207px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/THwWoZxkf_I/AAAAAAAAAMQ/TIc_Ptu23AE/s400/whdh.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5511304927364022258" /&gt;&lt;/a&gt;&lt;br /&gt;Here's a set of Westinghouse 50HD150-E electrical contacts we recently repaired.  See our contact information to the right and see what we can do for you.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4385260301549108760?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4385260301549108760'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4385260301549108760'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/08/westinghouse-50dh150-e-contacts.html' title='Westinghouse 50DH150-E Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/THwWoZxkf_I/AAAAAAAAAMQ/TIc_Ptu23AE/s72-c/whdh.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-7730355325899107026</id><published>2010-08-27T10:23:00.000-07:00</published><updated>2010-08-27T10:24:12.426-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Assorted Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/THf0mh0EJBI/AAAAAAAAAMA/ofB2ACKTL1Q/s1600/contactsshunts.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 218px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/THf0mh0EJBI/AAAAAAAAAMA/ofB2ACKTL1Q/s400/contactsshunts.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5510141611860042770" /&gt;&lt;/a&gt;Assorted contacts with braided shunts, complete with silver tungsten tips.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-7730355325899107026?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7730355325899107026'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7730355325899107026'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/08/assorted-contacts.html' title='Assorted Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/THf0mh0EJBI/AAAAAAAAAMA/ofB2ACKTL1Q/s72-c/contactsshunts.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4593505583176790660</id><published>2010-06-29T07:18:00.000-07:00</published><updated>2010-06-29T07:19:41.054-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Siemens Allis LA-600 Arcing Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/TCoA4GxP2fI/AAAAAAAAAL4/S1XGZdBRs_M/s1600/sala600.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 271px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/TCoA4GxP2fI/AAAAAAAAAL4/S1XGZdBRs_M/s400/sala600.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5488200059794217458" /&gt;&lt;/a&gt;Siemens Allis LA-600 Movable and Stationary Arcing contacts.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4593505583176790660?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4593505583176790660'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4593505583176790660'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/06/siemens-allis-la-600-arcing-contacts.html' title='Siemens Allis LA-600 Arcing Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/TCoA4GxP2fI/AAAAAAAAAL4/S1XGZdBRs_M/s72-c/sala600.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-2374357245186427282</id><published>2010-06-28T11:47:00.000-07:00</published><updated>2010-06-28T11:48:31.361-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>General Electric MC-6A Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/TCjuQSA4o1I/AAAAAAAAALw/jSXjndT_C2s/s1600/mc6a.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 273px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/TCjuQSA4o1I/AAAAAAAAALw/jSXjndT_C2s/s400/mc6a.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5487898109431817042" /&gt;&lt;/a&gt;Recently repaired General Electric MC-6A Electrical Contacts.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-2374357245186427282?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2374357245186427282'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2374357245186427282'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/06/general-electric-mc-6a-electrical.html' title='General Electric MC-6A Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/TCjuQSA4o1I/AAAAAAAAALw/jSXjndT_C2s/s72-c/mc6a.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8464284284064406426</id><published>2010-06-21T08:50:00.000-07:00</published><updated>2010-06-21T08:52:58.252-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Siemens Allis OCB 34.5 Electrical Contacts</title><content type='html'>Here are stationary contact finger clusters and movable contact that were repaired for a Siemens Allis 34.5 oil circuit breaker.  We can repair these are make new ones using copper, brass and copper tungsten.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/TB-KfqeY7GI/AAAAAAAAALo/APM9-l7sdCo/s1600/sa01.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 238px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/TB-KfqeY7GI/AAAAAAAAALo/APM9-l7sdCo/s400/sa01.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5485255147742882914" /&gt;&lt;/a&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/TB-KbhuojyI/AAAAAAAAALg/VbwK2OAebcQ/s1600/sa02.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 246px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/TB-KbhuojyI/AAAAAAAAALg/VbwK2OAebcQ/s400/sa02.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5485255076675620642" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8464284284064406426?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8464284284064406426'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8464284284064406426'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/06/siemens-allis-ocb-345-electrical.html' title='Siemens Allis OCB 34.5 Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/TB-KfqeY7GI/AAAAAAAAALo/APM9-l7sdCo/s72-c/sa01.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-693902666254997090</id><published>2010-03-25T08:02:00.001-07:00</published><updated>2010-03-25T08:05:21.384-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse AH-31 Electrical Contacts</title><content type='html'>Below are some parts we recently made for a Westinghouse AH-31 High Voltage Contactor. Shown are some movable and stationary contacts as well as two main contact supports which were machined using the customer's sample.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/S6t7KEyXKjI/AAAAAAAAALQ/5z9npFWteF8/s1600/ah-31a.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 252px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/S6t7KEyXKjI/AAAAAAAAALQ/5z9npFWteF8/s400/ah-31a.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5452587186876000818" /&gt;&lt;/a&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/S6t7G8xCNuI/AAAAAAAAALI/M5RLNFp9X5U/s1600/ah-31b.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 201px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/S6t7G8xCNuI/AAAAAAAAALI/M5RLNFp9X5U/s400/ah-31b.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5452587133183342306" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-693902666254997090?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/693902666254997090'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/693902666254997090'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/03/westinghouse-ah-31-electrical-contacts.html' title='Westinghouse AH-31 Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/S6t7KEyXKjI/AAAAAAAAALQ/5z9npFWteF8/s72-c/ah-31a.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-150519095815702012</id><published>2010-01-22T13:25:00.000-08:00</published><updated>2010-01-22T13:28:19.675-08:00</updated><title type='text'>Westinghouse DB-50 Electrical Contacts</title><content type='html'>Recently repaired Westinghouse DB-50 main and arcing Electrical Contacts.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/S1oYLWoXwaI/AAAAAAAAALA/R_93egLhROo/s1600-h/db50.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 205px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/S1oYLWoXwaI/AAAAAAAAALA/R_93egLhROo/s400/db50.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5429678884081090978" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/S1oYAZ1N5oI/AAAAAAAAAK4/ugrBGB3mZzQ/s1600-h/dbarc.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 263px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/S1oYAZ1N5oI/AAAAAAAAAK4/ugrBGB3mZzQ/s400/dbarc.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5429678695961716354" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-150519095815702012?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/150519095815702012'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/150519095815702012'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/01/westinghouse-db-50-electrical-contacts.html' title='Westinghouse DB-50 Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/S1oYLWoXwaI/AAAAAAAAALA/R_93egLhROo/s72-c/db50.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-3978787512095840648</id><published>2010-01-20T13:07:00.000-08:00</published><updated>2010-01-20T13:10:16.669-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse LF-50-H-430 Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/S1dwx8wlDgI/AAAAAAAAAKw/pdFpGJBEOhU/s1600-h/lf.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 274px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/S1dwx8wlDgI/AAAAAAAAAKw/pdFpGJBEOhU/s400/lf.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5428931879244205570" /&gt;&lt;/a&gt; One of our most common jobs involves repairing Westinghouse LF electrical contacts.  However, in some cases a customer may want extras made.  Here are a few pieces from a large order we recently completed where we made the LF contacts from copper and appropriate silver pads.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-3978787512095840648?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3978787512095840648'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3978787512095840648'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/01/westinghouse-lf-50-h-430-electrical.html' title='Westinghouse LF-50-H-430 Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/S1dwx8wlDgI/AAAAAAAAAKw/pdFpGJBEOhU/s72-c/lf.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-5671435220738372686</id><published>2010-01-19T13:29:00.000-08:00</published><updated>2010-01-19T13:32:03.744-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Allen-Bradley Motor Starter Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/S1YkWR6sDCI/AAAAAAAAAKo/puxcGoWoX1s/s1600-h/abb.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 241px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/S1YkWR6sDCI/AAAAAAAAAKo/puxcGoWoX1s/s400/abb.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5428566366026992674" /&gt;&lt;/a&gt;Recently repaired Allen-Bradley size 5 (Z34043) Motor Starter Electrical Contacts.  These parts came in with the tips all burned up.  We replaced the old pads with brand new contact material.  They're as good as new, if not better, and the customer didn't have to pay high prices for new contacts.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-5671435220738372686?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/5671435220738372686'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/5671435220738372686'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/01/allen-bradley-motor-starter-electrical.html' title='Allen-Bradley Motor Starter Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/S1YkWR6sDCI/AAAAAAAAAKo/puxcGoWoX1s/s72-c/abb.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-6435656811131151945</id><published>2010-01-07T11:50:00.000-08:00</published><updated>2010-01-07T11:52:27.097-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse 50-DH-205-D</title><content type='html'>We can repair the contacts from various Westinghouse DH breakers.  Below are some movable arcing, stationary arcing, and stationary mains from a Westinghouse 50-DH-205-D.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/S0Y7NUAGQEI/AAAAAAAAAKg/-zfAWQSKQ98/s1600-h/dharcing.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 271px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/S0Y7NUAGQEI/AAAAAAAAAKg/-zfAWQSKQ98/s400/dharcing.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5424087901107798082" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/S0Y7LAOs6lI/AAAAAAAAAKY/FuE8qJexiu8/s1600-h/dhmains.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 306px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/S0Y7LAOs6lI/AAAAAAAAAKY/FuE8qJexiu8/s400/dhmains.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5424087861440604754" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-6435656811131151945?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6435656811131151945'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6435656811131151945'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2010/01/westinghouse-50-dh-205-d.html' title='Westinghouse 50-DH-205-D'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/S0Y7NUAGQEI/AAAAAAAAAKg/-zfAWQSKQ98/s72-c/dharcing.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-1855803262797960830</id><published>2009-12-30T10:55:00.001-08:00</published><updated>2009-12-30T10:58:56.235-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Pringle Swithces</title><content type='html'>Below are some components of a Pringle Switch we recently refurbished.  There was very little arcing on the makeup portions, but the pivots were in bad shape from mechanical wear.  The customer sent in the effected parts to be serviced.  We disassembled the movable and stationary bolt up areas, cleaned and filled all the gouged portions, and then silver plated all the copper.  The resulting pieces were the same, if not better than brand new parts.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SzuiJi7-XiI/AAAAAAAAAKQ/aErz5fwxsZA/s1600-h/pring01.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 287px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SzuiJi7-XiI/AAAAAAAAAKQ/aErz5fwxsZA/s400/pring01.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5421104861351403042" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SzuiHGkPfEI/AAAAAAAAAKI/8GgYfh-0yYY/s1600-h/pring2.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 400px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SzuiHGkPfEI/AAAAAAAAAKI/8GgYfh-0yYY/s400/pring2.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5421104819375930434" /&gt;&lt;/a&gt;&lt;br /&gt;Give us a call to see what we can do for you!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-1855803262797960830?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1855803262797960830'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1855803262797960830'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/12/pringle-swithces.html' title='Pringle Swithces'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/SzuiJi7-XiI/AAAAAAAAAKQ/aErz5fwxsZA/s72-c/pring01.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8634102048712856752</id><published>2009-12-15T12:01:00.000-08:00</published><updated>2009-12-15T12:02:40.309-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>ITE KCS Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SyfrM9WdARI/AAAAAAAAAKA/OaCHRsW4wAI/s1600-h/ite.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 266px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SyfrM9WdARI/AAAAAAAAAKA/OaCHRsW4wAI/s400/ite.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5415555684796006674" /&gt;&lt;/a&gt;An assortment of electrical contacts from an ITE KSC air circuit breaker.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8634102048712856752?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8634102048712856752'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8634102048712856752'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/12/ite-kcs-electrical-contacts.html' title='ITE KCS Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/SyfrM9WdARI/AAAAAAAAAKA/OaCHRsW4wAI/s72-c/ite.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-7314863960066790648</id><published>2009-12-14T13:42:00.001-08:00</published><updated>2009-12-14T13:44:13.673-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>GE Magne Blast AM 4.16-75-0 Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/SyaxaI0XxVI/AAAAAAAAAJ4/bI6kx0223P8/s1600-h/mb.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 247px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/SyaxaI0XxVI/AAAAAAAAAJ4/bI6kx0223P8/s400/mb.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5415210664561460562" /&gt;&lt;/a&gt;Newly repaired electrical contacts from a General Electric Magne Blast AM 4.16-75-0 Circuit Breaker.  Use the contact information on the right of the screen to see what we can do for you!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-7314863960066790648?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7314863960066790648'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7314863960066790648'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/12/ge-magne-blast-am-416-75-0-electrical.html' title='GE Magne Blast AM 4.16-75-0 Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/SyaxaI0XxVI/AAAAAAAAAJ4/bI6kx0223P8/s72-c/mb.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-3308053919471987974</id><published>2009-12-11T05:30:00.000-08:00</published><updated>2009-12-11T05:32:23.912-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Isolating Switches</title><content type='html'>Here are stationary and movable contacts to what the customer identified as an Isolating Switches.  All the burned up areas were repaired and given silver plating.&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SyJJ0ZCrj1I/AAAAAAAAAJw/zXrsAhiDIZM/s1600-h/issw01.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 218px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SyJJ0ZCrj1I/AAAAAAAAAJw/zXrsAhiDIZM/s400/issw01.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5413970866476912466" /&gt;&lt;/a&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/SyJJyFZf24I/AAAAAAAAAJo/aLiyVK_SqVE/s1600-h/isw2.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 229px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/SyJJyFZf24I/AAAAAAAAAJo/aLiyVK_SqVE/s400/isw2.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5413970826844167042" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-3308053919471987974?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3308053919471987974'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3308053919471987974'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/12/isolating-switches.html' title='Isolating Switches'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/SyJJ0ZCrj1I/AAAAAAAAAJw/zXrsAhiDIZM/s72-c/issw01.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-1083591167789424035</id><published>2009-11-09T13:44:00.000-08:00</published><updated>2009-11-09T13:48:25.258-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse Air circuit Breaker Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/SviN1_YJbDI/AAAAAAAAAJg/t1K-T56tOsg/s1600-h/bolg+25+(2).jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 297px; height: 224px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/SviN1_YJbDI/AAAAAAAAAJg/t1K-T56tOsg/s400/bolg+25+(2).jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5402223711716207666" /&gt;&lt;/a&gt;These W/H ACB Stationary and Movable Contacts are tipped with silver tungsten pads.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-1083591167789424035?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1083591167789424035'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1083591167789424035'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/11/westinghouse-air-circuit-breaker.html' title='Westinghouse Air circuit Breaker Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/SviN1_YJbDI/AAAAAAAAAJg/t1K-T56tOsg/s72-c/bolg+25+(2).jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-2259298513649094625</id><published>2009-11-06T10:37:00.000-08:00</published><updated>2009-11-06T12:52:30.794-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>ITE 5HV-250 Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SvRtJfcaz8I/AAAAAAAAAJI/5DBM4ymRlD4/s1600-h/blog+2.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 196px; height: 130px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SvRtJfcaz8I/AAAAAAAAAJI/5DBM4ymRlD4/s400/blog+2.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5401061862951014338" /&gt;&lt;/a&gt;Recently repaired  ITE 5HV-250 Stationary Main Contacts.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-2259298513649094625?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2259298513649094625'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2259298513649094625'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/11/ite-5hv-250-electrical-contacts.html' title='ITE 5HV-250 Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/SvRtJfcaz8I/AAAAAAAAAJI/5DBM4ymRlD4/s72-c/blog+2.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-3620436739959715264</id><published>2009-11-05T10:34:00.000-08:00</published><updated>2009-11-06T12:51:13.423-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>General Electric  Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/SvSMAg7_IOI/AAAAAAAAAJY/q5wipvIHZog/s1600-h/1600.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 370px; height: 346px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/SvSMAg7_IOI/AAAAAAAAAJY/q5wipvIHZog/s400/1600.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5401095793593491682" /&gt;&lt;/a&gt;These General Electric Contact Set were repaired with Silver Tungsten Tips.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-3620436739959715264?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3620436739959715264'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3620436739959715264'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/11/general-electric-1600-amp-electrical.html' title='General Electric  Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/SvSMAg7_IOI/AAAAAAAAAJY/q5wipvIHZog/s72-c/1600.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8213999930898112499</id><published>2009-11-04T06:42:00.000-08:00</published><updated>2009-11-04T06:50:09.682-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>GE Magne Blast Movable Arcing Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SvGTYzQeNsI/AAAAAAAAAI4/XBK4869EyCs/s1600-h/bogger+(2).jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 291px; height: 211px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SvGTYzQeNsI/AAAAAAAAAI4/XBK4869EyCs/s400/bogger+(2).jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5400259482479376066" /&gt;&lt;/a&gt;Recently repaired movable arcing electrical contacts are from a General Electric Magne Blast circuit breaker.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8213999930898112499?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8213999930898112499'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8213999930898112499'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/11/ge-magna-blast-movable-arcing.html' title='GE Magne Blast Movable Arcing Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/SvGTYzQeNsI/AAAAAAAAAI4/XBK4869EyCs/s72-c/bogger+(2).jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4597752293352771972</id><published>2009-11-02T11:56:00.000-08:00</published><updated>2009-11-02T11:58:23.377-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Electrical Contacts for an AKR-30</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/Su85dIUkFXI/AAAAAAAAAIw/scWL_Z6zjVk/s1600-h/blog33.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 288px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/Su85dIUkFXI/AAAAAAAAAIw/scWL_Z6zjVk/s400/blog33.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5399597650853238130" /&gt;&lt;/a&gt;Here is a sampling of General Electric electrical contacts from an AKR-30.  Movable contacts, stationary contacts and the inner and outer pivots were repaired and silver plated.  Check out our &lt;a href="http://www.wwcomponents.net/"&gt;main site&lt;/a&gt; to see what we can do for you!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4597752293352771972?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4597752293352771972'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4597752293352771972'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/11/electrical-contacts-for-akr-30.html' title='Electrical Contacts for an AKR-30'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/Su85dIUkFXI/AAAAAAAAAIw/scWL_Z6zjVk/s72-c/blog33.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-1634604246470405616</id><published>2009-10-30T12:52:00.000-07:00</published><updated>2009-10-30T12:55:10.529-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Siemens LA 25 Movable Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SutEJTICp3I/AAAAAAAAAIo/JGL7FHX9slA/s1600-h/bolg.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 292px; height: 156px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SutEJTICp3I/AAAAAAAAAIo/JGL7FHX9slA/s400/bolg.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5398483504877184882" /&gt;&lt;/a&gt;These are off a siemens LA-25 Breaker. They are the movable contacts and were repaired with silver tungsten.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-1634604246470405616?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1634604246470405616'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1634604246470405616'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/10/siemens-la-25-movable-contacts.html' title='Siemens LA 25 Movable Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/SutEJTICp3I/AAAAAAAAAIo/JGL7FHX9slA/s72-c/bolg.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-6353239768023591529</id><published>2009-10-26T10:30:00.000-07:00</published><updated>2009-10-28T12:21:50.556-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Electrical Contacts from a Diverter Switch</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/SuXcyydo6tI/AAAAAAAAAIg/BO0p21hNfXU/s1600-h/blog+7.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 349px; height: 270px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/SuXcyydo6tI/AAAAAAAAAIg/BO0p21hNfXU/s400/blog+7.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5396962493571066578" /&gt;&lt;/a&gt;Here we have four different styles of contacts from a Diverter Switch we made in shop -- complete with contact pads and silver plated.  The customer was basically a "middle man" who didn't know exactly who the OEM was.  He sent in a sample of each style and we made these based on his samples.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-6353239768023591529?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6353239768023591529'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6353239768023591529'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/10/four-styles-of-electrical-contacts.html' title='Electrical Contacts from a Diverter Switch'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/SuXcyydo6tI/AAAAAAAAAIg/BO0p21hNfXU/s72-c/blog+7.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8784345122098665949</id><published>2009-10-19T12:55:00.000-07:00</published><updated>2009-10-19T12:55:00.557-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>GE AKR Stationary Arcing and  ALF Upper Field Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/StjP-OB01SI/AAAAAAAAAIY/B3Zfso57LJ4/s1600-h/blog.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 371px; height: 256px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/StjP-OB01SI/AAAAAAAAAIY/B3Zfso57LJ4/s400/blog.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5393289221600761122" /&gt;&lt;/a&gt;We repaired twelve GE AKR Stationary Arcing Contacts (five LHS, five RHS, and two centers) as well as one GE ALF Upper Field Contact Stud with appropriate contact tip material.  Give us a call to see what we can do for you in repairing burned up electrical contacts!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8784345122098665949?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8784345122098665949'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8784345122098665949'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/10/ge-akr-stationary-arcing-and-alf-upper.html' title='GE AKR Stationary Arcing and  ALF Upper Field Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/StjP-OB01SI/AAAAAAAAAIY/B3Zfso57LJ4/s72-c/blog.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-7581134045142121572</id><published>2009-10-16T13:56:00.000-07:00</published><updated>2009-10-16T13:56:00.171-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>General Electric Motor Starters</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/StTpp8clA1I/AAAAAAAAAIQ/0MRkoqXmP1s/s1600-h/blog+2.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 352px; height: 282px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/StTpp8clA1I/AAAAAAAAAIQ/0MRkoqXmP1s/s400/blog+2.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5392191560679228242" /&gt;&lt;/a&gt;&lt;center&gt;Recently repaired General Electric Size 7 Motor Starters&lt;/center&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-7581134045142121572?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7581134045142121572'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/7581134045142121572'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/10/general-electric-motor-starters.html' title='General Electric Motor Starters'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/StTpp8clA1I/AAAAAAAAAIQ/0MRkoqXmP1s/s72-c/blog+2.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-3984834728066494766</id><published>2009-10-15T13:46:00.000-07:00</published><updated>2009-10-15T13:46:00.144-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Tap Changer Electrical Contacts</title><content type='html'>Below are some parts from two different tap changers.  The basic hardware with the bolts could be reused, but the blades themselves were too badly burned.  We replaced the copper blades with new versions which were cut to the OEM specifications.  We also silver plated all the parts in shop.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/StTnRCurNCI/AAAAAAAAAIA/-8RZ_O3lHr8/s1600-h/blog+5.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 356px; height: 206px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/StTnRCurNCI/AAAAAAAAAIA/-8RZ_O3lHr8/s400/blog+5.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5392188933845759010" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/StTnOk3g7WI/AAAAAAAAAH4/GjbN3LDOJYE/s1600-h/Blog5a.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 349px; height: 220px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/StTnOk3g7WI/AAAAAAAAAH4/GjbN3LDOJYE/s400/Blog5a.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5392188891470032226" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-3984834728066494766?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3984834728066494766'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3984834728066494766'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/10/tap-changer-electrical-contacts.html' title='Tap Changer Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/StTnRCurNCI/AAAAAAAAAIA/-8RZ_O3lHr8/s72-c/blog+5.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4922469008516159247</id><published>2009-10-14T13:36:00.000-07:00</published><updated>2009-10-14T13:36:00.297-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>General Electric Limit Amp Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/StTk-ofeVoI/AAAAAAAAAHw/AWmGzlAq4MQ/s1600-h/blog.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 354px; height: 173px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/StTk-ofeVoI/AAAAAAAAAHw/AWmGzlAq4MQ/s400/blog.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5392186418541778562" /&gt;&lt;/a&gt;We can repair and manufacture various GE Limit Amp Electrical Contacts.  Shown is one of the most common, OEM part number 167A9956G1.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4922469008516159247?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4922469008516159247'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4922469008516159247'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/10/general-electric-limit-amp-electrical.html' title='General Electric Limit Amp Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/StTk-ofeVoI/AAAAAAAAAHw/AWmGzlAq4MQ/s72-c/blog.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-6996430348248529330</id><published>2009-10-13T13:28:00.000-07:00</published><updated>2009-10-13T13:33:48.815-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Mallory 8CC Electrical Contacts</title><content type='html'>Here are some movable and stationary Mallory 8CC Electrical Contacts.  We often repair these complete with silver plating.  The particular set seen here was used in Lexington Fire Pump, circa 1948.  The customer sent them in thinking we would have to make brand new ones based on the old burned up parts.  While we could have made new versions, the older parts were salvageable.  This resulted in a faster turn around time and saved the customer money.&lt;br /&gt;&lt;br /&gt;The first shot is how the contacts looked when they came to WW Components, and the second shot shows the exact same contacts after we refurbished them. &lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/StTjx-sBLEI/AAAAAAAAAHg/HltdBegZh3I/s1600-h/blog4A.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 355px; height: 269px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/StTjx-sBLEI/AAAAAAAAAHg/HltdBegZh3I/s400/blog4A.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5392185101650046018" /&gt;&lt;/a&gt;&lt;center&gt;&lt;span style="font-style:italic;"&gt;Mallory 8CC Electrical Contacts -- before.&lt;/span&gt;&lt;/center&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/StTj0qYhDbI/AAAAAAAAAHo/5tYCPEIPnvo/s1600-h/blog4.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 367px; height: 163px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/StTj0qYhDbI/AAAAAAAAAHo/5tYCPEIPnvo/s400/blog4.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5392185147739147698" /&gt;&lt;/a&gt;&lt;center&gt;&lt;span style="font-style:italic;"&gt;Mallory 8CC Electrical Contacts -- after!&lt;/span&gt;&lt;/center&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-6996430348248529330?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6996430348248529330'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6996430348248529330'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/10/mallory-8cc-electrical-contacts.html' title='Mallory 8CC Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/StTjx-sBLEI/AAAAAAAAAHg/HltdBegZh3I/s72-c/blog4A.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-2221896800973778338</id><published>2009-10-12T13:53:00.000-07:00</published><updated>2009-10-13T13:56:38.526-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Siemens 456D Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/StTpJ6y7ODI/AAAAAAAAAII/5RPHaoq3GCI/s1600-h/blog+3.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 370px; height: 169px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/StTpJ6y7ODI/AAAAAAAAAII/5RPHaoq3GCI/s400/blog+3.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5392191010480273458" /&gt;&lt;/a&gt;&lt;center&gt;&lt;i&gt;Recently repaired Siemens 456D Electrical Contacts&lt;/i&gt;&lt;/center&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-2221896800973778338?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2221896800973778338'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2221896800973778338'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/10/siemens-456d-electrical-contacts.html' title='Siemens 456D Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/StTpJ6y7ODI/AAAAAAAAAII/5RPHaoq3GCI/s72-c/blog+3.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-9193968970489507076</id><published>2009-09-25T06:58:00.001-07:00</published><updated>2009-09-25T07:05:14.449-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>General Electric FKD Contact Set</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SrzNtLgi1GI/AAAAAAAAAHY/iooMpyW2ViQ/s1600-h/fkd1.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 371px; height: 280px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SrzNtLgi1GI/AAAAAAAAAHY/iooMpyW2ViQ/s400/fkd1.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5385405430495368290" /&gt;&lt;/a&gt;This is one of the most common types of contacts we work on; the electrical contacts from a General Electric FKD oil circuit breaker.  The set above is how they generally come in to our shop.  Thirty-six stationary contacts and six small arcing contacts in their aluminum housings and six movable rods make up the set. We completely disassemble, repair the contacts with the proper silver tungsten, and reassemble so they're ready for instillation.  Below are the same contacts after we repaired them...&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/SrzMobLEtOI/AAAAAAAAAHI/UOso3DuK-Fs/s1600-h/fkd2.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 352px; height: 252px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/SrzMobLEtOI/AAAAAAAAAHI/UOso3DuK-Fs/s400/fkd2.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5385404249289307362" /&gt;&lt;/a&gt;&lt;center&gt;&lt;span style="font-style:italic;"&gt;General Electric FKD Stationary Contact Assemblies&lt;/span&gt;&lt;/center&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/SrzMlszGpvI/AAAAAAAAAHA/eOaOX3wG0mY/s1600-h/fkd3.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 369px; height: 241px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/SrzMlszGpvI/AAAAAAAAAHA/eOaOX3wG0mY/s400/fkd3.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5385404202481002226" /&gt;&lt;/a&gt;&lt;center&gt;&lt;span style="font-style:italic;"&gt;General Electric FKD Movable Contact Rods&lt;/span&gt;&lt;/center&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-9193968970489507076?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/9193968970489507076'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/9193968970489507076'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/09/general-electric-fkd-contact-set.html' title='General Electric FKD Contact Set'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/SrzNtLgi1GI/AAAAAAAAAHY/iooMpyW2ViQ/s72-c/fkd1.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4402548570595900488</id><published>2009-09-23T11:29:00.000-07:00</published><updated>2009-09-23T11:32:47.695-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Allis Chalmers BZ-40-A Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SrppHmK6AMI/AAAAAAAAAG4/aSGk0ZqijEc/s1600-h/ac.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 357px; height: 207px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SrppHmK6AMI/AAAAAAAAAG4/aSGk0ZqijEc/s400/ac.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5384731883701141698" /&gt;&lt;/a&gt;Here are some contacts from a set of Allis Chalmers BZ-40-A Oil Circuit Breaker we repaired.  The pads on the stationary double contact were burned up.  We upgraded from plain copper to the appropriate tungsten contact.  The movable rods were also in bad shape, but after our repairs, they look brand new.  With the proper contact material, they will even operate better than before!  Check out the contact info to the right and call us to see what we can do for you!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4402548570595900488?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4402548570595900488'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4402548570595900488'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/09/allis-chalmers-bz-40-contacts.html' title='Allis Chalmers BZ-40-A Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/SrppHmK6AMI/AAAAAAAAAG4/aSGk0ZqijEc/s72-c/ac.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-6165166564913136049</id><published>2009-09-22T08:34:00.000-07:00</published><updated>2010-04-22T08:38:31.610-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Federal Pacific OCB Shoe Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/S9Bs1BRFZbI/AAAAAAAAALY/A5JVv3MPkPY/s1600/fpocb.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 181px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/S9Bs1BRFZbI/AAAAAAAAALY/A5JVv3MPkPY/s400/fpocb.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5462986006129370546" /&gt;&lt;/a&gt;&lt;br /&gt;An assortment of Federal Pacific OCB Contacts a.k.a. "shoe contacts".  We can manufacture and repair various styles of these contacts. The one front and center is FB-4461, an example from a FP Model #RHE-78-115-10000.  Check out the contact information to the right and call or email for a quote today!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-6165166564913136049?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6165166564913136049'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6165166564913136049'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/09/federal-pacific-ocb-shoe-contacts.html' title='Federal Pacific OCB Shoe Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/S9Bs1BRFZbI/AAAAAAAAALY/A5JVv3MPkPY/s72-c/fpocb.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-9184621567437263397</id><published>2009-09-11T11:42:00.000-07:00</published><updated>2009-09-11T11:44:50.032-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>General Electric FH-209 Brass Contact Assemblies</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/SqqaGFVTQII/AAAAAAAAAGo/6WFgRqaYeDc/s1600-h/GEDC0410.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 359px; height: 312px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/SqqaGFVTQII/AAAAAAAAAGo/6WFgRqaYeDc/s400/GEDC0410.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5380282134148890754" /&gt;&lt;/a&gt;Here are three examples of General Electric FH-209 Brass Contact Assemblies we made using brass and copper layered shunts.  Everything you see in the photo came from our shop -- completely assembled and ready for the customer.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-9184621567437263397?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/9184621567437263397'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/9184621567437263397'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/09/general-electric-fh-209-brass-contact.html' title='General Electric FH-209 Brass Contact Assemblies'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/SqqaGFVTQII/AAAAAAAAAGo/6WFgRqaYeDc/s72-c/GEDC0410.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8817857348469964799</id><published>2009-09-10T11:44:00.000-07:00</published><updated>2009-09-11T11:47:08.412-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse Size 5 Motor Starters</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SqqaxX3XhVI/AAAAAAAAAGw/eUVdsGVrNGY/s1600-h/GEDC0427.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 364px; height: 263px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SqqaxX3XhVI/AAAAAAAAAGw/eUVdsGVrNGY/s400/GEDC0427.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5380282877857989970" /&gt;&lt;/a&gt;This is rather common job for us at WW Components; repair of the Westinghouse Size 5 Motor Starter contacts.  These often arrive with burned up round pads, but we put on brand new silver tungsten pads  with the &lt;span style="font-style:italic;"&gt;proper&lt;/span&gt; contours.  Check out our contact information to the right and give us a call!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8817857348469964799?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8817857348469964799'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8817857348469964799'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/09/westinghouse-size-5-motor-starters.html' title='Westinghouse Size 5 Motor Starters'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/SqqaxX3XhVI/AAAAAAAAAGw/eUVdsGVrNGY/s72-c/GEDC0427.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-2754831595661027300</id><published>2009-09-03T14:20:00.000-07:00</published><updated>2009-09-03T14:25:38.796-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Cutler Hammer Size 3 (6-43-6) Three-pole set of electrical contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SqAz1JK706I/AAAAAAAAAGg/KRU8DzDT_b4/s1600-h/blog1.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 364px; height: 287px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SqAz1JK706I/AAAAAAAAAGg/KRU8DzDT_b4/s400/blog1.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5377354943168238498" /&gt;&lt;/a&gt;These Cutler Hammer contacts were repaired with silver tungsten pads and silver plated.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-2754831595661027300?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2754831595661027300'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2754831595661027300'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/09/cutler-hammer-size-3-6-43-6-three-pole.html' title='Cutler Hammer Size 3 (6-43-6) Three-pole set of electrical contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/SqAz1JK706I/AAAAAAAAAGg/KRU8DzDT_b4/s72-c/blog1.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8335635315771073826</id><published>2009-09-03T09:15:00.000-07:00</published><updated>2009-09-03T09:15:00.249-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Westinghouse DS-416 Arcing Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/Sp6aXTPQo2I/AAAAAAAAAGY/KqQgFeYt4lA/s1600-h/blog+2.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 370px; height: 344px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/Sp6aXTPQo2I/AAAAAAAAAGY/KqQgFeYt4lA/s400/blog+2.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5376904730218898274" /&gt;&lt;/a&gt;This is for a Westinghouse DS-416 Circuit breaker. We have three movable arcing contacts and three right-hand and three left-hand stationary arcing contacts. They all have silver tungsten pads and are silver plated.  We can repair the contacts from all of the various Westinghouse DS types.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8335635315771073826?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8335635315771073826'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8335635315771073826'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/09/westinghouse-ds-416-arcing-contacts.html' title='Westinghouse DS-416 Arcing Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/Sp6aXTPQo2I/AAAAAAAAAGY/KqQgFeYt4lA/s72-c/blog+2.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-6797518116888320118</id><published>2009-09-02T13:44:00.000-07:00</published><updated>2009-09-01T13:51:21.828-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Allen-Bradley 100-Line Motor Starter Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/Sp2IaQKKxuI/AAAAAAAAAGQ/RcRuScGO6gY/s1600-h/blogger+1.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 346px; height: 246px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/Sp2IaQKKxuI/AAAAAAAAAGQ/RcRuScGO6gY/s400/blogger+1.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5376603514745833186" /&gt;&lt;/a&gt;This is a Three-pole set of Allen Bradley 100-Line Motor Starter contacts. They were repaired with silver tungsten pads and silver plated.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-6797518116888320118?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6797518116888320118'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6797518116888320118'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/09/allen-bradley-100-line-motor-starter.html' title='Allen-Bradley 100-Line Motor Starter Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/Sp2IaQKKxuI/AAAAAAAAAGQ/RcRuScGO6gY/s72-c/blogger+1.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8118497979486705756</id><published>2009-09-01T11:59:00.001-07:00</published><updated>2009-09-01T12:13:53.074-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>GE AK-2-25 Electrical contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/Sp1vbE_SuxI/AAAAAAAAAGI/skXOfUhyIXA/s1600-h/bloger.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 346px; height: 241px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/Sp1vbE_SuxI/AAAAAAAAAGI/skXOfUhyIXA/s400/bloger.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5376576041136601874" /&gt;&lt;/a&gt;We manufactured these for a GE AK-2-25 Electrical circuit breaker. Three movable assemblies and six right-hand and six left hand stationary contacts. The pads are silver tungsten.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8118497979486705756?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8118497979486705756'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8118497979486705756'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/09/ge-ak-2-25-electrical-contacts.html' title='GE AK-2-25 Electrical contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/Sp1vbE_SuxI/AAAAAAAAAGI/skXOfUhyIXA/s72-c/bloger.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-348644671897076730</id><published>2009-09-01T11:59:00.000-07:00</published><updated>2009-09-01T12:00:33.225-07:00</updated><title type='text'>GE AK-2-25 Movable Assemblies and Stationary Electrical contacts</title><content type='html'>&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-348644671897076730?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/348644671897076730'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/348644671897076730'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/09/ge-ak-2-25-movable-assemblies-and.html' title='GE AK-2-25 Movable Assemblies and Stationary Electrical contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-6714527438593615959</id><published>2009-08-26T11:21:00.000-07:00</published><updated>2009-08-26T11:26:27.975-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Siemens SDO Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/SpV9_mYxdII/AAAAAAAAAGA/GhetUpI6PhQ/s1600-h/blog.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 366px; height: 339px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/SpV9_mYxdII/AAAAAAAAAGA/GhetUpI6PhQ/s400/blog.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5374340261926237314" /&gt;&lt;/a&gt;Two sets of Siemens SDO Oil Circuit Breaker electrical contacts repaired with brand new pads and silver plated.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-6714527438593615959?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6714527438593615959'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6714527438593615959'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/08/siemens-sdo-electrical-contacts.html' title='Siemens SDO Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/SpV9_mYxdII/AAAAAAAAAGA/GhetUpI6PhQ/s72-c/blog.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-5301253051422393688</id><published>2009-08-25T06:59:00.000-07:00</published><updated>2009-08-25T07:06:37.366-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Furnas Size 5 motor starter electrical contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SpPuiQDSFDI/AAAAAAAAAF4/XQtrb5g7yyo/s1600-h/blog.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 358px; height: 327px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SpPuiQDSFDI/AAAAAAAAAF4/XQtrb5g7yyo/s400/blog.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5373901052574831666" /&gt;&lt;/a&gt;Furnas size 5 (75KB14 )Motor Starter contacts.  We can repair different sizes and OEM motor starter contacts from size 0 all the way up to size 9 and everything in between!  Check out our main &lt;a href="http://www.wwcomponents.net/"&gt;website&lt;/a&gt; on more of our services!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-5301253051422393688?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/5301253051422393688'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/5301253051422393688'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/08/furnas-size-5-motor-starter-electrical.html' title='Furnas Size 5 motor starter electrical contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/SpPuiQDSFDI/AAAAAAAAAF4/XQtrb5g7yyo/s72-c/blog.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4974988109244110062</id><published>2009-08-19T12:00:00.000-07:00</published><updated>2009-08-19T12:00:01.696-07:00</updated><title type='text'>ITE K-1600 Movable Arcing Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SompCTuE-QI/AAAAAAAAAFo/SciPYlON6zs/s1600-h/K-1600.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 349px; height: 259px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SompCTuE-QI/AAAAAAAAAFo/SciPYlON6zs/s400/K-1600.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5371009887734397186" /&gt;&lt;/a&gt;Three Movable Arcing Contacts repaired with Silver Tungsten pads.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4974988109244110062?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4974988109244110062'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4974988109244110062'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/08/ite-k-1600-movable-arcing-electrical.html' title='ITE K-1600 Movable Arcing Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/SompCTuE-QI/AAAAAAAAAFo/SciPYlON6zs/s72-c/K-1600.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8417777328269919242</id><published>2009-08-18T10:52:00.001-07:00</published><updated>2009-08-18T10:58:30.280-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>GE Magne Blast AM-4.16 Movable Arcing Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SorqjUBUYLI/AAAAAAAAAFw/cP7p843Glnc/s1600-h/Ge+Magne+Blast+Movable+Arcing+Contacts.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 361px; height: 269px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SorqjUBUYLI/AAAAAAAAAFw/cP7p843Glnc/s400/Ge+Magne+Blast+Movable+Arcing+Contacts.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5371363397983297714" /&gt;&lt;/a&gt;These GE AM-4.16-350 Movable Arcing Contacts were repaired with Silver Tungsten pads and then Silver Plated.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8417777328269919242?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8417777328269919242'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8417777328269919242'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/08/ge-magne-blast-am-416-movable-arcing.html' title='GE Magne Blast AM-4.16 Movable Arcing Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/SorqjUBUYLI/AAAAAAAAAFw/cP7p843Glnc/s72-c/Ge+Magne+Blast+Movable+Arcing+Contacts.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-2924551405898729865</id><published>2009-08-17T11:55:00.000-07:00</published><updated>2009-08-18T10:58:20.582-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>GE Magne Blast AM-4.16 Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/SomoDnYi-hI/AAAAAAAAAFg/D1NY6LrYWYw/s1600-h/Dan+kahns.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 349px; height: 238px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/SomoDnYi-hI/AAAAAAAAAFg/D1NY6LrYWYw/s400/Dan+kahns.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5371008810681039378" /&gt;&lt;/a&gt;Three Movable Arcing contacts from a GE Magne Blast AM-4.16-250 breaker repaired with Silver Tungsten pads.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-2924551405898729865?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2924551405898729865'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2924551405898729865'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/08/ge-magne-blast-am-416-electrical.html' title='GE Magne Blast AM-4.16 Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/SomoDnYi-hI/AAAAAAAAAFg/D1NY6LrYWYw/s72-c/Dan+kahns.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-3701286583542942710</id><published>2009-08-14T11:40:00.000-07:00</published><updated>2009-08-14T11:43:36.859-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Stationary Switch Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SoWv9E9dwOI/AAAAAAAAAFY/b-swo97JBhg/s1600-h/Swicth+contacts.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 363px; height: 324px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SoWv9E9dwOI/AAAAAAAAAFY/b-swo97JBhg/s400/Swicth+contacts.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5369891594547609826" /&gt;&lt;/a&gt;Three spring loaded stationary contacts for a USCO switch. We repaired the burned up area and silver plated the copper.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-3701286583542942710?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3701286583542942710'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3701286583542942710'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/08/stationary-switch-electrical-contacts.html' title='Stationary Switch Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/SoWv9E9dwOI/AAAAAAAAAFY/b-swo97JBhg/s72-c/Swicth+contacts.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-3426279395661332069</id><published>2009-08-13T12:18:00.000-07:00</published><updated>2009-08-13T12:22:22.365-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>Hubbell  DC Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/SoRnfIXlJzI/AAAAAAAAAFQ/ZC9t-5K-b9U/s1600-h/west.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 358px; height: 153px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/SoRnfIXlJzI/AAAAAAAAAFQ/ZC9t-5K-b9U/s400/west.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5369530440252466994" /&gt;&lt;/a&gt;A set of Hubbell DC Contactor contacts with brand new pads. Check out our contact information to the right and see what we can do for you.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-3426279395661332069?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3426279395661332069'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3426279395661332069'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/08/hubbell-dc-electrical-contacts.html' title='Hubbell  DC Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/SoRnfIXlJzI/AAAAAAAAAFQ/ZC9t-5K-b9U/s72-c/west.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8847195523670983341</id><published>2009-08-11T11:41:00.000-07:00</published><updated>2009-08-11T11:46:54.830-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>K-600 Movable Arcing Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/SoG774rIoHI/AAAAAAAAAFI/PMreJNKcHwM/s1600-h/ITE.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 357px; height: 336px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/SoG774rIoHI/AAAAAAAAAFI/PMreJNKcHwM/s400/ITE.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5368778868302323826" /&gt;&lt;/a&gt;ITE K-600 Movable Arcing Electrical Contacts. We can repair all of the K-600 contacts, but the movable arcing is the most requested. Check out our &lt;a href="http://www.wwcomponents.net/"&gt;website&lt;/a&gt; to see what we can do for you.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8847195523670983341?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8847195523670983341'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8847195523670983341'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/08/k-600-movable-arcing-electrical.html' title='K-600 Movable Arcing Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/SoG774rIoHI/AAAAAAAAAFI/PMreJNKcHwM/s72-c/ITE.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4786737579100731468</id><published>2009-08-10T08:14:00.000-07:00</published><updated>2009-08-11T10:54:12.633-07:00</updated><title type='text'>Magne Blast Main Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SoGK00Q7k2I/AAAAAAAAAEY/9d4WVJXr3OU/s1600-h/magblast.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 219px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SoGK00Q7k2I/AAAAAAAAAEY/9d4WVJXr3OU/s400/magblast.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5368724870789829474" /&gt;&lt;/a&gt;Twelve newly repaired GE Magne Blast movable main electrical contacts.  We can refurbish the different Magne Blast contacts from various breaker types.  Check out our main &lt;a href="http://www.wwcomponents.net/"&gt;website&lt;/a&gt; on more of our services!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4786737579100731468?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4786737579100731468'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4786737579100731468'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/08/magne-blast-main-electrical-contacts.html' title='Magne Blast Main Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/SoGK00Q7k2I/AAAAAAAAAEY/9d4WVJXr3OU/s72-c/magblast.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-3314660159567122144</id><published>2009-08-07T10:46:00.000-07:00</published><updated>2009-08-11T11:47:52.501-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Electrical Contacts'/><title type='text'>MA-350C Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SoGu8RB5AYI/AAAAAAAAAFA/rdxyRMRFKMU/s1600-h/sa.jpg"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 359px; height: 174px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SoGu8RB5AYI/AAAAAAAAAFA/rdxyRMRFKMU/s400/sa.jpg" border="0" alt=""id="BLOGGER_PHOTO_ID_5368764581189058946" /&gt;&lt;/a&gt;Here is a set of Siemens MA-350C Arcing Contacts that we recently repaired with brand new pads - three left hand movable arcing, three right hand movable arcing, and three stationary arcing.  Check out our &lt;a href="http://www.wwcomponents.net/"&gt;website&lt;/a&gt; to see what we can do for you.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-3314660159567122144?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3314660159567122144'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/3314660159567122144'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/08/ma-350c-electrical-contacts.html' title='MA-350C Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/SoGu8RB5AYI/AAAAAAAAAFA/rdxyRMRFKMU/s72-c/sa.jpg' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-6724253194800832906</id><published>2009-07-22T12:06:00.000-07:00</published><updated>2009-07-22T12:09:29.464-07:00</updated><title type='text'>IC7162 Limitamp Controllers</title><content type='html'>Some before and after shots of a set of GE IC7162 Limitamp Controllers GEH-3065 we recently refurbished.  We repaired the old copper make up areas with silver tungsten pads.  Check our our site: &lt;a href="http://www.wwcomponents.net"&gt;WWComponents.net&lt;/a&gt; to see what we can do for you!&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SmdjbIyLh_I/AAAAAAAAAEQ/663ZPcgxneo/s1600-h/ge11.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 330px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SmdjbIyLh_I/AAAAAAAAAEQ/663ZPcgxneo/s400/ge11.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5361363199273437170" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SmdjZL33m1I/AAAAAAAAAEI/VYZxLjzzj9o/s1600-h/ge12.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 269px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SmdjZL33m1I/AAAAAAAAAEI/VYZxLjzzj9o/s400/ge12.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5361363165742865234" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-6724253194800832906?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6724253194800832906'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6724253194800832906'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/07/ic7162-limitamp-controllers.html' title='IC7162 Limitamp Controllers'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_nySxne7Qx8g/SmdjbIyLh_I/AAAAAAAAAEQ/663ZPcgxneo/s72-c/ge11.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-6627734988118419163</id><published>2009-06-23T08:12:00.000-07:00</published><updated>2009-06-23T08:13:48.122-07:00</updated><title type='text'>ITE HK Contact Set</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/SkDw_NOtk5I/AAAAAAAAAEA/VUvls3FAKR4/s1600-h/ite.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 269px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/SkDw_NOtk5I/AAAAAAAAAEA/VUvls3FAKR4/s400/ite.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5350541325989942162" /&gt;&lt;/a&gt;A portion of ITE HK Contacts we recently repaired.  See the information on the sidebar to call for a quote today on repairing YOUR electrical contacts!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-6627734988118419163?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6627734988118419163'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/6627734988118419163'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/06/ite-hk-contact-set.html' title='ITE HK Contact Set'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/SkDw_NOtk5I/AAAAAAAAAEA/VUvls3FAKR4/s72-c/ite.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-5615679493731336496</id><published>2009-06-08T13:21:00.000-07:00</published><updated>2009-06-08T13:23:07.002-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='GE'/><title type='text'>AKR10D-50H Electrical Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/Si1y0rhoOFI/AAAAAAAAAD4/httaIQiGFSU/s1600-h/GEDC0147.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 207px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/Si1y0rhoOFI/AAAAAAAAAD4/httaIQiGFSU/s400/GEDC0147.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5345054582121183314" /&gt;&lt;/a&gt;&lt;br /&gt;Here's a group of contacts from a set of General Electric AKR-10D-50H.  All contacts were given brand new pads.  After they were plated and cleaned up, they looked and worked like a brand new set!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-5615679493731336496?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/5615679493731336496'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/5615679493731336496'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/06/akr10d-50h-electrical-contacts.html' title='AKR10D-50H Electrical Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/Si1y0rhoOFI/AAAAAAAAAD4/httaIQiGFSU/s72-c/GEDC0147.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-8373880593310867648</id><published>2009-05-28T10:36:00.000-07:00</published><updated>2009-05-28T10:38:59.196-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Westinghouse'/><title type='text'>Westinghouse DBF-40 Arcing Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/Sh7L3cNFXQI/AAAAAAAAADw/lIBQKydrbVg/s1600-h/dbf40.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 233px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/Sh7L3cNFXQI/AAAAAAAAADw/lIBQKydrbVg/s400/dbf40.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5340930361432300802" /&gt;&lt;/a&gt;&lt;br /&gt;Here are some Westinghouse DBF-40 stationary and movable arcing contacts we recently repaired.  They came in with bad pitting all along the makeup areas.  We removed the old pads and replaced them with brand new contact material.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-8373880593310867648?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8373880593310867648'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/8373880593310867648'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/05/westinghouse-dbf-40-arcing-contacts.html' title='Westinghouse DBF-40 Arcing Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/Sh7L3cNFXQI/AAAAAAAAADw/lIBQKydrbVg/s72-c/dbf40.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-4628244454653854736</id><published>2009-03-20T13:18:00.000-07:00</published><updated>2009-03-20T13:23:38.284-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Cutler Hammer'/><title type='text'>Cutler Hammer Contacts</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/ScP6RR5VIKI/AAAAAAAAADo/mdM42M7SLlk/s1600-h/chmm.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 277px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/ScP6RR5VIKI/AAAAAAAAADo/mdM42M7SLlk/s400/chmm.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5315367159995900066" /&gt;&lt;/a&gt;Here are some Culter Hammer upper and lower stationary main contacts attached to a phenolic board along with the movable contacts with studs.  These normally arrive with small circular pads as the contact points.  We can repair these with full surface pads on the stationary contacts.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-4628244454653854736?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4628244454653854736'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/4628244454653854736'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/03/cutler-hammer-contacts.html' title='Cutler Hammer Contacts'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_nySxne7Qx8g/ScP6RR5VIKI/AAAAAAAAADo/mdM42M7SLlk/s72-c/chmm.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-2542280284044405848</id><published>2009-03-09T13:48:00.000-07:00</published><updated>2009-03-09T13:52:57.978-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='GM7S'/><category scheme='http://www.blogger.com/atom/ns#' term='Westinghouse'/><title type='text'>GM-7S Stationary Contact</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SbWBo8Wr1uI/AAAAAAAAADg/7lZHF3qp2pI/s1600-h/arm11.JPG"&gt;&lt;img style="display:block; margin:0px auto 10px; text-align:center;cursor:pointer; cursor:hand;width: 360px; height: 161px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SbWBo8Wr1uI/AAAAAAAAADg/7lZHF3qp2pI/s400/arm11.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5311293875949393634" /&gt;&lt;/a&gt;Here is part of a Westinghouse GM-7S Stationary Contact.  We repaired a whole set of these along with the movable stabs recently.  The contact tips were replaced and all the hardware was cleaned up.  The finished assemblies looked and operated as brand new products.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-2542280284044405848?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2542280284044405848'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2542280284044405848'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/03/gm-7s-stationary-contact.html' title='GM-7S Stationary Contact'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/SbWBo8Wr1uI/AAAAAAAAADg/7lZHF3qp2pI/s72-c/arm11.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-2316282985229255139</id><published>2009-03-06T12:26:00.000-08:00</published><updated>2009-03-06T12:29:21.747-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Swtiches'/><category scheme='http://www.blogger.com/atom/ns#' term='Before and After'/><title type='text'>USCO Switch Repair</title><content type='html'>Below are before and after shots of a USCO HH6 600 AMP switch.  We repair these as well as 1200 AMP versions for various customers.  If the copper blades are too burned up, we can make new ones and reuse the cast hardware.  We also do our own silver plating using 99.9% pure silver.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/SbGHIkuJ3ZI/AAAAAAAAACw/qyjVxfQYxkM/s1600-h/usco01.JPG"&gt;&lt;img style="float:left; margin:0 10px 10px 0;cursor:pointer; cursor:hand;width: 320px; height: 171px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/SbGHIkuJ3ZI/AAAAAAAAACw/qyjVxfQYxkM/s320/usco01.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5310174017012489618" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_nySxne7Qx8g/SbGHGSsLc8I/AAAAAAAAACo/cjRBfNq74yA/s1600-h/usco02.JPG"&gt;&lt;img style="float:left; margin:0 10px 10px 0;cursor:pointer; cursor:hand;width: 320px; height: 169px;" src="http://4.bp.blogspot.com/_nySxne7Qx8g/SbGHGSsLc8I/AAAAAAAAACo/cjRBfNq74yA/s320/usco02.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5310173977812628418" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-2316282985229255139?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2316282985229255139'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/2316282985229255139'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/03/usco-switch-repair.html' title='USCO Switch Repair'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGHIkuJ3ZI/AAAAAAAAACw/qyjVxfQYxkM/s72-c/usco01.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-1465227542607163258</id><published>2009-03-04T21:08:00.000-08:00</published><updated>2009-03-04T21:12:33.824-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='FPE'/><category scheme='http://www.blogger.com/atom/ns#' term='Finger Clusters'/><title type='text'>FPE Finger Cluster</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/Sa9fKqyyfCI/AAAAAAAAACg/N_pvsTzBrI0/s1600-h/cluster01.JPG"&gt;&lt;img style="float:left; margin:0 10px 10px 0;cursor:pointer; cursor:hand;width: 282px; height: 320px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/Sa9fKqyyfCI/AAAAAAAAACg/N_pvsTzBrI0/s320/cluster01.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5309567122583747618" /&gt;&lt;/a&gt;Federal Pacific Finger Cluster.  We can resilver and repair your FPE Finger clusters as well as clusters from other OEMs.  Be sure to visit our site: &lt;a href="http://www.wwcomponents.net/"&gt;wwcomponents.net&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-1465227542607163258?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1465227542607163258'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/1465227542607163258'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/03/fpe-finger-cluster.html' title='FPE Finger Cluster'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/Sa9fKqyyfCI/AAAAAAAAACg/N_pvsTzBrI0/s72-c/cluster01.JPG' height='72' width='72'/></entry><entry><id>tag:blogger.com,1999:blog-8394680923097880543.post-9185675231080182781</id><published>2009-02-25T13:12:00.000-08:00</published><updated>2009-03-06T12:29:49.515-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Swtiches'/><category scheme='http://www.blogger.com/atom/ns#' term='GE'/><title type='text'>GE LG-218 Disconnect Switch Assembly</title><content type='html'>We mostly do electrical contact repair work here at WW Components, but every once in a while, we get RFQ's on parts that are beyond repair.  In some cases, the repair work would be too involved and it becomes less expensive and faster to make new parts from scratch.  Such was the case with a recent job we did with a GE LG-218 Disconnect Switch.  It was made out of copper with brass and phosphorus bronze hardware.  Below are some pictures of the customer's part and the ones we made.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SaW0rKH2BFI/AAAAAAAAAAs/XfsHaOcl200/s1600-h/ww022509a.JPG"&gt;&lt;img style="float:left; margin:0 10px 10px 0;cursor:pointer; cursor:hand;width: 320px; height: 155px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SaW0rKH2BFI/AAAAAAAAAAs/XfsHaOcl200/s320/ww022509a.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5306846389470626898" /&gt;&lt;/a&gt;This is the customer's burned up part that was sent in as a sample.  The makeup area was completely burned and the silver pivots on the back were ruined from mechanical wear.&lt;br clear="all"&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SaW1stEwd-I/AAAAAAAAAA0/wtBFt9TwDy0/s1600-h/ww2.JPG"&gt;&lt;img style="float:left; margin:0 10px 10px 0;cursor:pointer; cursor:hand;width: 320px; height: 297px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SaW1stEwd-I/AAAAAAAAAA0/wtBFt9TwDy0/s320/ww2.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5306847515544418274" /&gt;&lt;/a&gt;A closeup shot of the damaged makeup area.  &lt;br clear="all"&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_nySxne7Qx8g/SaW0mRlhmKI/AAAAAAAAAAc/pNdjWUga5ao/s1600-h/ww3.JPG"&gt;&lt;img style="float:left; margin:0 10px 10px 0;cursor:pointer; cursor:hand;width: 320px; height: 126px;" src="http://2.bp.blogspot.com/_nySxne7Qx8g/SaW0mRlhmKI/AAAAAAAAAAc/pNdjWUga5ao/s320/ww3.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5306846305574820002" /&gt;&lt;/a&gt;Here's one of our newly made parts using copper and silver. &lt;br clear="all"&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_nySxne7Qx8g/SaW0kHfjurI/AAAAAAAAAAU/u-1CdlM2Ogk/s1600-h/ww4.JPG"&gt;&lt;img style="float:left; margin:0 10px 10px 0;cursor:pointer; cursor:hand;width: 320px; height: 302px;" src="http://3.bp.blogspot.com/_nySxne7Qx8g/SaW0kHfjurI/AAAAAAAAAAU/u-1CdlM2Ogk/s320/ww4.JPG" border="0" alt=""id="BLOGGER_PHOTO_ID_5306846268505701042" /&gt;&lt;/a&gt;Makeup area detail of a new part.&lt;br clear="all"&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_nySxne7Qx8g/SaW0hpzvCBI/AAAAAAAAAAM/Ev9lLIk0dFU/s1600-h/ww5.JPG"&gt;&lt;img style="margin: 0pt 10px 10px 0pt; float: left; cursor: pointer; width: 320px; height: 118px;" src="http://1.bp.blogspot.com/_nySxne7Qx8g/SaW0hpzvCBI/AAAAAAAAAAM/Ev9lLIk0dFU/s320/ww5.JPG" alt="" id="BLOGGER_PHOTO_ID_5306846226177525778" border="0" /&gt;&lt;/a&gt;All six new switches ready to be shipped to the customer for instillation.  &lt;br clear="all"&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8394680923097880543-9185675231080182781?l=wwcomponents.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/9185675231080182781'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8394680923097880543/posts/default/9185675231080182781'/><link rel='alternate' type='text/html' href='http://wwcomponents.blogspot.com/2009/02/ge-lg-218-disconnect-switch-assembly.html' title='GE LG-218 Disconnect Switch Assembly'/><author><name>WW Components</name><uri>http://www.blogger.com/profile/01208114322371778501</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='25' src='http://3.bp.blogspot.com/_nySxne7Qx8g/SbGd7IuPxBI/AAAAAAAAAC4/xGp4aVE-wEc/S220/wwc.JPG'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_nySxne7Qx8g/SaW0rKH2BFI/AAAAAAAAAAs/XfsHaOcl200/s72-c/ww022509a.JPG' height='72' width='72'/></entry></feed>
